Secondary Air Injection (AIR) Valve -N112-, Checking
Secondary Air Injection (AIR) Solenoid Valve -N112-, checking
Checking Secondary Air Injection (AIR) Solenoid Valve -N112- electrically
- Disconnect connector at Secondary Air Injection (AIR) Solenoid Valve -N112-.
- Perform a resistance measurement between the valve terminals using V.A.G 1526 hand multimeter.
Specified value: 25 to 35 ohms.
If specified value is not obtained
- Replace Secondary Air Injection (AIR) solenoid valve.
Checking voltage supply from Secondary Air Injection (AIR) Solenoid Valve -N112-
- Disconnect connector at Secondary Air Injection (AIR) Solenoid Valve -N112-.
Check fuse for Secondary Air Injection (AIR) solenoid valve.
Check wire for continuity from terminal 1 on connector to fuse according to wiring diagram.
Specified value: max. 0.5 ohms
Check Fuel Pump (FP) relay and activation
Checking activation of Secondary Air Injection (AIR) solenoid valve
- Connect V.A.G 1598/19 test box to wiring harness.
- Check wire from terminal 2 on connector to socket E2 of test box for short circuit to Ground (GND).
- If voltage tester does not blink, check wire for continuity from terminal 2 on connector to socket E2 of test box.
- Eliminate short circuit to Ground (GND) or open circuit in wiring between terminal 2 on connector and terminal 2 of connector E if necessary.
- If there is no malfunction in wire connection, replace MFI control module and generate readiness code