Checking Components and Wiring
Checking Components And Wiring
- Ignition off
Check the fuse for the circuit. If the fuse is blown, check the cable. Check for a short-circuit to ground.
Check the resistance of the reset valve.
Disconnect the engine control module (ECM).
Check the signal cable for the relevant camshaft reset valve. Check for an open-circuit.
Measure between:
- Control module #A91 (#B31) and reset valve camshaft #2, exhaust (bank 1).
- Control module #A90 (#B30) and reset valve camshaft #2, exhaust (bank 2).
Check the voltage supply cable for the relevant camshaft reset valve. Check for an open-circuit.
Measure between:
- System relay and reset valve camshaft #1, exhaust (bank 1).
- System relay and reset valve camshaft #1, exhaust (bank 2).
Remedy as necessary.
Other Information
- Connecting the breakout box
- Signal specification, engine control module (ECM)
- Component specifications
- Variable valve timing solenoid, replacing
- Checking wiring and terminals
Continue: Refer to Verification. Verification