Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Signal Too Low. Intermittent Fault






Signal too low. Intermittent fault

Checking the connectors and components




- Ignition off.
Check the leak diagnostic pump, system relay and control module connectors. Check for contact resistance and oxidation according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Check the cable between leak diagnostic pump terminal #2 and control module terminal #35. Check for an open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Remedy as necessary.

Other information:
- To connect the breakout box, see Connecting the breakout box. EMS 2000 Connecting The Breakout Box. EMS 2000
- To replace the leak diagnostic pump, see Replacing the leak diagnostic pump Service and Repair.













Continue - Fault-tracing information

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).

Do you want to view the information again?

Yes - Attempt New Test

No - FAULT FOUND

------------------------

Attempt New Test - Checking the connectors and components

FAULT FOUND - DONE

-------------------------------------------------