Checking the Resistance In the Cable - I
Checking The Resistance In The Cable
- Ignition off.
- Disconnect the control module.
- Vacuum pump removed.
Connect an ohmmeter between vacuum pump connector terminal 2 and control module connector terminal 9.
The ohmmeter should read approximately 0 Ohm.
OK: Continue with Next Procedure.
NOT OK: Refer to Checking For an Open-Circuit - I. Checking For an Open-Circuit - I