Checking the Cable to the Vacuum Pump - I
Checking The Cable To The Vacuum Pump
- Ignition off.
- Disconnect the vacuum pump.
- Control module disconnected.
Connect a voltmeter between vacuum pump connector terminal 2 and ground.
The ohmmeter should read infinite resistance.
OK: Continue with Next Procedure.
NOT OK: Refer to Checking For A Short-Circuit - II. Checking For A Short-Circuit - II