Procedures
Ultrasonic Or Glass Breakage Control Module
Preparation
- Make a note of the radio code.
- Turn ignition key to position 0.
- Remove the battery ground lead. Otherwise you might create diagnostic trouble codes.
Removing Control Module
Remove:
- The control module is located down at the bottom of the ventilator motor.
- Remove the lower cover on the passenger side.
- Undo connectors (green and blue).
- Remove the screws (2x) and remove the control module.
Installing Control Module
Install:
- Position control module and mount the screws (2x).
- Install connectors.
- Install cover on passenger side.
- Turn ignition key to position II.
- Mount battery ground lead.
- Always read the diagnostic trouble codes in the VGLA alarm system.