Signal Too Low. Intermittent Fault
Signal too low. Intermittent fault
Intermittent fault
Check the cable between climate control module terminal #B1 and outside temperature sensor terminal #2. Check for an intermittent short-circuit to ground.
Remedy as necessary.
Other information:
- To replace the outside temperature sensor, see Outside temperature sensor Removal and Replacement
- To connect the breakout box, see Connecting the breakout box, climate control module Connecting The Breakout Box
- For the voltage of the signal cable, see Climate control signal specifications Signal Specification
- Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Intermittent fault
FAULT FOUND - DONE
-------------------------------------------------