Signal Too High. Permanent Fault
Signal too high. Permanent fault
Checking connectors
- Ignition off
- Check the evaporator temperature sensor and the climate control module connector B (16-pin) Check for contact resistance and oxidation. Remedy if necessary.
Check for damage carefully
- Reinstall the components, reconnect the connectors etc.
- Ignition on
- Read off the evaporator temperature.
Check that the evaporator temperature is correct. Compare with the actual air temperature.
The fault was loose connections in the connectors if the evaporator temperature sensor is OK.
Other information
- To remove the control module, see Comfort module Removal and Replacement
- To replace the evaporator temperature sensor, see Temperature sensor evaporator Removal and Replacement
- Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault
Is the temperature reading OK?
Yes - FAULT FOUND
No - Checking components and wiring
-------------------------------------------------
Checking components and wiring
Check the resistance of the evaporator temperature sensor. Take the readings between evaporator temperature sensor terminals #3 and #4.
Check the signal cable between climate control module terminal #B3 and evaporator temperature sensor terminal #4. Check for an open-circuit. Check for a short-circuit to supply voltage.
Check the ground lead between control module terminal #B4 and evaporator temperature sensor terminal #3. Check for an open-circuit. Check for a short-circuit to supply voltage.
Hint: A short-circuit on the ground lead may have been caused by a short-circuit to supply voltage. Always check the signal cable for this fault cause as well.
Remedy as necessary.
Other information:
- For the resistance values, see Electrical / electronic system specifications [1][2]Specifications
- To replace the evaporator temperature sensor, see Temperature sensor evaporator Removal and Replacement
- To connect the breakout box, see Connecting the breakout box, climate control module Connecting The Breakout Box
- For the voltage of the signal cable, see Climate control signal specifications Signal Specification
- Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault
Continue - Verification
-------------------------------------------------
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off
- Reinstall the connectors, components etc.
- Ignition on
- Read off the evaporator temperature.
Check that the evaporator temperature is correct. The fault has been remedied if the evaporator temperature is correct.
Is the temperature reading OK?
Yes - FAULT FOUND
No - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - Exit fault-tracing
No - Attempt New Test
------------------------
Attempt New Test - Checking connectors
-------------------------------------------------