Faulty Signal. Intermittent Fault
Faulty signal. Intermittent fault
Checking the wiring
- Ignition off
- Disconnect the battery negative lead
- Disconnect the side impact sensor connector
- Disconnect the SRS control module connector
- Connect the battery negative lead.
Warning! There must not be anyone inside the passenger compartment when the battery is connected.
Check the connectors. Check for contact resistance and oxidation according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Measure the resistance between the side impact sensor:
- terminal #1 and control module terminal #57 (#32)
- terminal #2 and control module terminal #58 (#33).
check for an intermittent open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
The resistance must be approximately 0 ohms. If not there is an open-circuit.
Measure the resistance between control module terminal #57 (#32) and chassis ground. Measure the resistance between side impact sensor terminal #1 and chassis ground. Check for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
The resistance must be infinite.
Measure the resistance between control module terminal #57 (#32) and chassis ground. Measure the resistance between side impact sensor terminal #1 and chassis ground. Check for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
The voltage must be 0 V. If not there is a short-circuit to supply voltage.
Remedy as necessary.
Other information:
- To access and replace the control module see SRS control module Removal and Replacement
- To access and replace the side impact sensor, see SIPS sensor (B-post) SIPS Sensor (B-Post)
- To connect the breakout box, see Connecting the breakout box Connecting The Breakout Box
- For information about signals, see Signal specification Signal Description. Supplementary Restraint System (SRS).
Continue - Fault-tracing information
DONE
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
FAULT-TRACING FAILED - DONE
Attempt New Test - Checking the wiring
-------------------------------------------------