Signal Too High. Intermittent Fault
Signal too high. Intermittent fault
Checking wiring and connectors
- Ignition off.
Check the cable between control module terminal #65 and rear heated oxygen sensor (HO2S) connector terminal #2. Check for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Remedy as necessary.
Other information
- To connect the breakout box and access the control module, see Connecting the breakout box. EMS 2000 Connecting The Breakout Box. EMS 2000
- To access or replace the rear heated oxygen sensor (HO2S), see Replacing lambda sond rear Removal and Replacement
- For information about signals see Signal specification Signal Specification.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Checking wiring and connectors
FAULT FOUND - DONE
-------------------------------------------------