Signal Too High. Intermittent Fault
Signal too high. Intermittent fault
Intermittent fault
Check the signal cable between climate control module (CCM) terminal #A9 and left seat heater module terminal A#2. Check for an intermittent short-circuit to supply voltage.
Note! If the seat heater is activated at high or low level, the signal in the cable is pulsed between approximately 0 V and battery voltage.
Remedy as necessary.
Other information:
- To access and replace the seat heater pad, see Heater pad backrest, replacing Heater Pad Backrest, Replacing and Heater pad seat cushion Heater Pad Seat Cushion
- To remove the control module, see Comfort module Removal and Replacement
- To connect the breakout box, see Connecting the breakout box, climate control module Connecting The Breakout Box
- For the voltage of the cable, see Climate control signal specifications Signal Specification
- Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Intermittent fault
-------------------------------------------------