Signal Too High. Intermittent Fault
Signal too high. Intermittent fault
Intermittent fault
Check the wiring between transmission control module (TCM) terminal #2 and terminal #3 on the 8-pin transmission connector. Check the wiring between control module terminal #30 and terminal #4 on the 8-pin transmission connector. Check for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Hint: Check solenoid SLT by measuring the resistance between terminals #3 and #4 on the transmission connector. The ohmmeter should read 5-5.6 ohms at 20°C.
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box, AW55-50/51SN Connecting The Breakout Box
- To disconnect the transmission connectors, see Transmission connectors, AW55-50/51SN Transmission Connectors
- For information about signals, see Signal description. Transmission control module (TCM), AW55-50/51SN Signal Description.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
FAULT FOUND - DONE
Attempt New Test - Intermittent fault
-------------------------------------------------