Signal Too Low. Permanent Fault
Signal too low. Permanent fault
Checking the wiring and component
- Ignition off.
Check the signal cable between control module terminal #10 and system relay terminal #2. Check for a short-circuit to ground according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault. Check for an open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
Hint: With the ignition on and the system relay disconnected, the voltage between system relay terminal #1 and ground should be approximately 12V.
Try a new system relay if no fault is found during the above fault-tracing.
Remedy as necessary.
Other information
- To connect the breakout box and access the control module, see Connecting the breakout box. EMS 2000 Connecting The Breakout Box. EMS 2000
- To access or replace the system relay, see Engine compartment Engine Compartment
- For information about signals see Signal specification Signal Specification.
Continue - Verification
-------------------------------------------------
Verification
Verification
- Ignition on.
Activate the system relay. Check that the relay clicks and the fuel pump (FP) starts when it is activated.
Is the function OK?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFICATION FAILED - Fault-tracing information
VERIFIED - FAULT FOUND
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - Exit fault-tracing
No - Attempt New Test
------------------------
Attempt New Test - Checking the wiring and component
-------------------------------------------------