Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Checking Cables




Checking Cables






Check the control module and the damper motor connectors for contact resistance and oxidation according to Checking wiring and terminals - Permanent faults. Checking Wiring and Terminals

Check the signal cable between the MCC control module #B3 and the damper motor terminal 3 for an open-circuit according to Checking wiring and terminals - Permanent faults and a short-circuit to supply voltage according to Checking wiring and terminals - Permanent faults. Checking Wiring and Terminals

Check the ground lead between the MCC control module #B1 and the damper motor terminal 1 for an open-circuit according to Checking wiring and terminals - Permanent faults. Checking Wiring and Terminals

Check the cable for power supply between the MCC control module #B2 and the damper motor terminal 2 for a short-circuit to supply voltage according to Checking wiring and terminals - Permanent faults.

If the cables are OK, try a new recirculation damper motor.

Remedy as necessary.

Other information:

- To connect the breakout box Connection of Breakout Box MCC
- Voltage on signal cable varies between approximately 0-5 V depending on damper motor position. Damper motor power supply should be approximately 5 V. For other values refer to Signal Specification MCC Signal Specification MCC

After performing this procedure Self-Adjusting of Shutter Motor End Position