Faulty Signal






Faulty signal

Lamp test




- Ignition off.
- Ignition on.
Note how the indicator lamp on the combined instrument panel reacts.
1. The indicator lamp lights for 3 seconds.
2. The indicator lamp lights and is on continuously.
3. The indicator lamp does not light at all, it lights when the ignition is switched off or it goes out the when the ignition is switched on.

Select one of the following alternatives to continue.

1 - Checking for a short-circuit, intermittent fault

2 - Checking for a short-circuit

3 - Checking for a short-circuit

-------------------------------------------------

Checking for a short-circuit, intermittent fault
Check the cable between control module #1 and indicator lamp #B24 on the combined instrument panel for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults and for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.

Note! At normal function, the voltage at #1 is approximately 0 V only during the time the lamp check is made (until approximately three seconds after the ignition is switched on). The voltage then increases to battery voltage.

Other information
- For information about signals, see Signal specification Signal Specification, Immobilizer.
- To connect the breakout box, see Connecting the breakout box Connecting the Breakout Box.









Select Continue.

Continue - Fault-tracing information
FAULT FOUND

-------------------------------------------------

Checking for a short-circuit
Check the cable between control module #1 and indicator lamp #B24 on the combined instrument panel for a short-circuit to ground according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.

Other information
- For information about signals, see Signal specification Signal Specification, Immobilizer.
- To connect the breakout box, see Connecting the breakout box Connecting the Breakout Box.









Select Continue.

Continue - Verification

-------------------------------------------------

Checking for a short-circuit

Hint: There is a short-circuit to +15 in the cable to control module #1 if the indicator lamp does not light.
There is a short-circuit to +30 in the cable to control module #1 if the indicator lamp lights when the ignition is switched off.

Check the cable between control module #1 and indicator lamp #B24 on the combined instrument panel for a short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.

Note! At normal function, the voltage at #1 is approximately 0 V only during the time the lamp check is made (until approximately three seconds after the ignition is switched on). The voltage then increases to battery voltage.

Other information
- For information about signals, see Signal specification Signal Specification, Immobilizer.
- To connect the breakout box, see Connecting the breakout box Connecting the Breakout Box.









Select Continue.

Continue - Verification

-------------------------------------------------

Verification




Verification

Verification




- Ignition on.
Activate the immobilizer indicator lamp.





Does the indicator lamp function as it should?

Yes - VERIFIEDPAPER

No - VERIFICATION FAILED

------------------------

VERIFIED - FAULT FOUND

VERIFICATION FAILED - Fault-tracing information

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.

Do you want to exit fault-tracing?

Yes - FAULT-TRACING FAILED

No - Attempt New Test

------------------------

FAULT-TRACING FAILED - FAULT-TRACING FAILED

Attempt New Test - Lamp test

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).

Do you want to view the information again?

Yes - Attempt New Test

No - FAULT FOUND

------------------------

Attempt New Test - Lamp test

FAULT FOUND - FAULT FOUND