Signal Too High
Signal too high
Checking the interior lighting
- Check that the courtesy lighting door switch is in the door position.
- Ignition off.
Remove the key from the ignition switch.
The interior light should light.
Does the courtesy lighting light?
Yes - Intermittent fault
No - Checking the wiring
-------------------------------------------------
Checking the wiring
- Ignition off.
Check the cable between control module #A24 and roof light #5 for a short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
Other information:
- For further information about signals and other values, see Signal specification, lock and alarm, (VGLA) Signal Specification.
- To connect the breakout box, see Connecting the breakout box, lock and alarm (VGLA) Connecting The Breakout Box, Lock And Alarm (VGLA).
Select "Continue" when the fault has been remedied
Continue - Verification
-------------------------------------------------
Verification
Hint: After carrying out the repair, check that the fault has been remedied as follows:
- Ignition off.
- Reinstall the connectors, components etc.
- The control switch for the interior lighting is in the door position.
- Ignition on.
- Ignition off.
Remove the key from the ignition switch.
The interior light should light.
Does the courtesy lighting light?
Yes - FAULT FOUND
No - Fault-tracing information
No Fault Found
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
FAULT-TRACING FAILED - No Fault Found
Attempt New Test - Checking the interior lighting
-------------------------------------------------
Intermittent fault
Check the cable between control module #A24 and roof light #5 for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
Other information:
- For further information about signals and other values, see Signal specification, lock and alarm, (VGLA) Signal Specification.
- To connect the breakout box, see Connecting the breakout box, lock and alarm (VGLA) Connecting The Breakout Box, Lock And Alarm (VGLA).
Select "Continue" when complete.
Continue - Fault-tracing information
No Fault Found
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
FAULT FOUND - FAULT FOUND
Attempt New Test - Checking the interior lighting
-------------------------------------------------