Signal Too Low
Signal too low
Checking the signal from the central locking switch
Read off the central locking switch status when the switch is unaffected.
The value should be HIGH.
Is the value HIGH?
Yes - Intermittent fault
No - Checking the central locking switch
-------------------------------------------------
Checking the central locking switch
- Remove the central locking switch from the dashboard
- Disconnect the central locking switch.
Read off the central locking switch status.
If the value is now HIGH it means that the central locking switch is defective.
Is the value HIGH?
Yes - Replacing the component
No - Checking the wiring
-------------------------------------------------
Replacing the component
Try a new central locking switch.
Select Continue.
Continue - Verification
-------------------------------------------------
Checking the wiring
Check the cable between the control module terminal #A4 and central locking switch terminal #3 for a short-circuit to ground according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
Other information:
- For further information about signals and other values, see Signal specification, lock and alarm, (VGLA) Signal Specification
- To connect the breakout box, see Connecting the breakout box, lock and alarm (VGLA) Connecting The Breakout Box, Lock And Alarm (VGLA).
Select Continue.
Continue - Verification
-------------------------------------------------
Verification
Hint: After repairs have been completed, they must be verified as follows to ensure that the fault has been eliminated:
- Ignition on
- Reinstall the connectors, components etc.
Read off the central locking switch status, the value should be HIGH in the unaffected position and LOW in the affected position.
Is the value OK?
Yes - FAULT FOUND
No - Fault-tracing information
No Fault Found
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
FAULT-TRACING FAILED - No Fault Found
Attempt New Test - Checking the signal from the central locking switch
-------------------------------------------------
Intermittent fault
Check the cable between the control module terminal #A4 and central locking switch terminal #3 for a short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults ,
Other information:
- For further information about signals and other values, see Signal specification, lock and alarm, (VGLA) Signal Specification
- To connect the breakout box, see Connecting the breakout box, lock and alarm (VGLA) Connecting The Breakout Box, Lock And Alarm (VGLA).
Select Continue.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
FAULT FOUND - FAULT FOUND
Attempt New Test - Checking the signal from the central locking switch
-------------------------------------------------