Signal Too Low
Signal too low
Checking the signal from the control switch
- Ignition off.
- Check that all doors are shut.
Try locking and unlocking the car with the key.
Is the function OK?
Yes - Intermittent fault
No - Checking the control switch in the lock unit
-------------------------------------------------
Checking the control switch in the lock unit
- Ignition off.
- Remove the driver's door door panel according to Front door Front Door.
- Remove the control switch connector.
- Ignition on.
Read off the control switch status.
The value should be HIGH.
Is the value HIGH?
Yes - Replacing the component
No - Checking the wiring
-------------------------------------------------
Replacing the component
Try a new control switch according to Door lock front door Door Lock Front Door.
Select Continue.
Continue - Verification
-------------------------------------------------
Checking the wiring
- Ignition off.
Check the cable between control module #A18 and control switch #3 for a short-circuit to ground according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
Other information:
- For further information about signals and other values, see Signal specification, lock and alarm, (VGLA) Signal Specification.
- To connect the breakout box, see Connecting the breakout box, lock and alarm (VGLA) Connecting The Breakout Box, Lock And Alarm (VGLA).
Select "Continue" when the fault has been remedied.
Continue - Verification
-------------------------------------------------
Verification
Hint: After carrying out the repair, check that the fault has been remedied as follows:
- Ignition off.
- Reinstall the connectors, components etc.
- Ignition on.
Read off the control switch status
The value should be HIGH.
Is the value HIGH?
Yes - FAULT FOUND
No - Fault-tracing information
No Fault Found
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
FAULT-TRACING FAILED - No Fault Found
Attempt New Test - Checking the signal from the control switch
-------------------------------------------------
Intermittent fault
Check the cable between control module #A18 and control switch #3 for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
Other information:
- For further information about signals and other values, see Signal specification, lock and alarm, (VGLA) Signal Specification.
- To connect the breakout box, see Connecting the breakout box, lock and alarm (VGLA) Connecting The Breakout Box, Lock And Alarm (VGLA).
Select Continue.
Continue - Fault-tracing information
No Fault Found
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
FAULT FOUND - FAULT FOUND
Attempt New Test - Checking the signal from the control switch
-------------------------------------------------