Signal Too Low. Permanent Fault
Signal too low. Permanent fault
Checking wiring
- Ignition off.
Disconnect VGLA control module connector A.
Connect an ohmmeter between #A10 and ground. Check for a short-circuit to ground according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
Remedy as necessary.
Other information:
- For further information about signals and other values, see Signal specification, lock and alarm, (VGLA) Signal Specification.
- To connect the breakout box, see Connecting the breakout box, lock and alarm (VGLA) Connecting The Breakout Box, Lock And Alarm (VGLA).
- To access the control module connector, see VGLA-control module VGLA-Control Module.
- To access the control module connector, see Sensor module, replacement Service and Repair.
Was a fault detected?
Yes - Verification
No - No Fault Found
-------------------------------------------------
Verification
Verification
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off.
- Reinstall the connectors, components etc.
- Close all the doors, then lock the doors using the internal central locking switch.
- Ignition on.
Try to activate the central locking system collision function, the doors should unlock.
Did the doors unlock?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFICATION FAILED - Fault-tracing information
VERIFIED - FAULT FOUND
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
FAULT-TRACING FAILED - No Fault Found
Attempt New Test - Checking wiring
-------------------------------------------------