Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Signal Too Low. Intermittent Fault






Signal too low. Intermittent fault

Checking wiring




- Ignition off.
Disconnect VGLA control module connector A.
Connect an ohmmeter between #A10 and ground. Check for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
Remedy as necessary.

Other information:
- For further information about signals and other values, see Signal specification, lock and alarm, (VGLA) Signal Specification.
- To connect the breakout box, see Connecting the breakout box, lock and alarm (VGLA) Connecting The Breakout Box, Lock And Alarm (VGLA).
- To access the control module connector, see VGLA-control module VGLA-Control Module.
- To access the control module connector, see Sensor module, replacement Service and Repair.





Select Continue.

Continue - Fault-tracing information
No Fault Found

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).

Do you want to view the information again?

Yes - Attempt New Test

No - FAULT FOUND

------------------------

FAULT FOUND - FAULT FOUND

Attempt New Test - Checking wiring

-------------------------------------------------