Internal Fault. Intermittent Fault
Internal fault. Intermittent fault
Intermittent fault
Check the cable between control module terminal #B3 (29) and tilt sensor terminal #1. Check for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults. Check for an intermittent open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
Check the cable between control module terminal #A17 (17) and tilt sensor terminal #2. Check for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults. Check for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.Check for an intermittent open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
Check the cable between the control module for the tilt sensor terminal #5 and ground. Check for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults. Check for an intermittent open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
Remedy as necessary.
Other information:
- To access and replace the tilt sensor (4 door and 5 door), see Tilt sensor Tilt Sensor For The Alarm.
Select "Continue" when complete.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
FAULT FOUND - FAULT FOUND
Attempt New Test - Intermittent fault
-------------------------------------------------