Intermittent Fault, Signal Too Low
Intermittent fault, signal too low
Checking cables
Check signal cable between engine control module (ECM) terminal 44 and heated oxygen sensor (HO2S) terminal 4 for an intermittent short-circuit to ground and remedy according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
If no fault can be found in the above fault-tracing try a new heated oxygen sensor (HO2S).
Other information
- To connect the test box, see Connecting the breakout box. EMS 2000 Connecting The Breakout Box. EMS 2000.
- To replace the heated oxygen sensor (HO2S), see Replacing lambda probes Replacing Lambda Probes.
Continue - FAULT FOUND
-------------------------------------------------