Faulty Signal. Intermittent Fault
Faulty signal. Intermittent fault
Check
Check the signal cables between engine control module (ECM) terminals 57 and 27 and transmission control module (TCM) terminals 14 and 27 for a short-circuit to ground and remedy according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults and for a short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults , short-circuit to each other and for an open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
Check the engine control module (ECM) and transmission control module (TCM) connectors for contact resistance and oxidation according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
Check in particular for damage, or loose terminal pins.
Other information:
- For information about signals, see Signal specification EMS2000
- To connect the breakout box, see Connecting the breakout box. EMS 2000 Connecting The Breakout Box. EMS 2000.
Select Continue.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Check
FAULT FOUND - DONE
-------------------------------------------------