Signal Missing. Permanent Fault
Signal missing. Permanent fault
Checking the signal cable
- Ignition off
- Connect the breakout box
- Ignition on.
Connect a voltmeter between the breakout box terminal #B5 and ground.
Hint:
Other information
- To connect the breakout box, see Connecting the breakout box. EMS 2000 Connecting The Breakout Box. EMS 2000.
The voltmeter should read 5 V.
OK - Checking wiring and terminals
Not OK - Checking wiring and terminals
-------------------------------------------------
Checking wiring and terminals
Check the cable between engine control module (ECM) terminal #20 and DSA control module terminal #15. Check for an open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
Remedy as necessary.
Select Continue.
Continue - Verification
-------------------------------------------------
Checking wiring and terminals
Check the cable between engine control module (ECM) terminal #20 and DSA control module terminal #15. Check for a short-circuit to ground according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault. Check for a short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
Remedy as necessary.
Select Continue.
Continue - Verification
-------------------------------------------------
Verification
- Ignition off
- Reconnect the connectors, reinstall components etc.
- Start the engine.
Read off diagnostic trouble codes (DTCs).
Did the status change to intermittent?
Yes - FAULT FOUND
No - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
FAULT-TRACING FAILED - FAULT-TRACING FAILED
Attempt New Test - Checking the signal cable
-------------------------------------------------