Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Signal Too Low. Intermittent Fault






Signal too low. Intermittent fault

Checking components and wiring




- Ignition off.
Check that the resistance between idle air control (IAC) valve terminals 1 and 2 is approximately 10 ohms at +20°C.
Check signal cable between engine control module (ECM) terminal 64 and idle air control (IAC) valve terminal 2 for an intermittent short-circuit to ground. Remedy according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.

Other information
- To connect the breakout box, see Connecting the breakout box. EMS 2000 Connecting The Breakout Box. EMS 2000.













Select Continue.

Continue - Fault-tracing information

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).

Do you want to view the information again?

Yes - Attempt New Test

No - FAULT FOUND

------------------------

Attempt New Test - Checking components and wiring

FAULT FOUND - DONE

-------------------------------------------------