Signal Too Low. Intermittent Fault
Intermittent fault, signal too low
Checking wiring
Check that the resistance between the air conditioning (A/C) relay terminals 1 and 2 is approximately 105 ohms at +20°C.
Check the signal cable between the engine control module (ECM) terminal #68 and air conditioning (A/C) relay terminal 2 for an intermittent short-circuit to ground and remedy according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
Other information
- To connect the breakout box, see Connecting the breakout box. EMS 2000 Connecting The Breakout Box. EMS 2000.
Select Continue.
Continue - FAULT FOUND
-------------------------------------------------