Signal Too High. Intermittent Fault
Signal too high. Intermittent fault
Checking wiring and components
Check the signal cable between ignition coil terminal 1 and engine control module (ECM) terminal #32 (ECM-38), #1 (ECM-3A) for an intermittent short-circuit to supply voltage and remedy according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
If no faults are found in the above fault-tracing try a new ignition coil.
Other information
- To connect the breakout box, see Connecting the breakout box. EMS 2000 Connecting The Breakout Box. EMS 2000.
- To replace the ignition coil see Ignition coil(s), replacement Replacing Ignition Coils.
Select Continue.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Checking wiring and components
FAULT FOUND - DONE
-------------------------------------------------