Signal Too High. Intermittent Fault
Signal too high. Intermittent fault
Checking components and wiring
Check that the resistance in the heated oxygen sensor (HO2S) preheating element, measured between probe terminals 1 and 2, is approximately 5-10 ohms at +20° C
Check the signal cable between engine control module (ECM) terminal 63 and heated oxygen sensor (HO2S) terminal 2 for an intermittent short-circuit to supply voltage. Remedy according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
Remedy as necessary.
Other information
- To connect the breakout box, see Connecting the breakout box. EMS 2000 Connecting The Breakout Box. EMS 2000
- To access / replace the heated oxygen sensor (HO2S), see Replace the front heated oxygen sensor (HO2S) Replace The Front Heated Oxygen Sensor (HO2S).
Select Continue.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Checking components and wiring
FAULT FOUND - DONE
-------------------------------------------------