Signal Missing. Intermittent Fault
Signal missing. Intermittent fault
Checking components and wiring
Check the heated oxygen sensor (HO2S) and engine control module (ECM) connectors for contact resistance and oxidation according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
Check that the resistance in the heated oxygen sensor (HO2S) preheating element, between terminals 1 and 2, is approximately 5-10 ohms at +20°C.
Check the signal cable between engine control module (ECM) terminal 63 and heated oxygen sensor (HO2S) terminal 2 for an intermittent open-circuit. Remedy according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
Remedy as necessary.
Other information
- To connect the breakout box, see Connecting the breakout box. EMS 2000 Connecting The Breakout Box. EMS 2000
- To access / replace the heated oxygen sensor (HO2S), see Replace the front heated oxygen sensor (HO2S) Replace The Front Heated Oxygen Sensor (HO2S).
Select Continue.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Checking components and wiring
FAULT FOUND - DONE
-------------------------------------------------