Short-Circuit To Ground
Short-circuit to ground
Checking resistance
- Ignition off
- Disconnect the connector from the blower fan power unit
- ECC control module connected.
Connect an ohmmeter between ground (0 V) and terminal 3 on the connector for the blower fan power unit.
The ohmmeter should read infinity.
OK - Replacing the component
Not OK - Checking for a short-circuit
-------------------------------------------------
Replacing the component
- Replace the blower fan power unit.
Select "Continue" when the component has been replaced.
Continue - Verification
-------------------------------------------------
Checking for a short-circuit
Check the cable between ECC control module connector terminal 28 and terminal 3 on the connector for the blower fan motor power unit for a short-circuit to ground according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
Select Continue when the fault has been remedied.
Continue - Verification
-------------------------------------------------
Verification
Verification
Hint: Check after repair that the fault has been rectified.
- Ignition off.
- Connect the connectors, reinstall components etc.
- ECC control module connected.
- Engine running.
- VCT 2000 connected to the data link connector (DLC).
Establish communication with the ECC system.
Select Continue.
Continue - Verification, continued
------------------------
Verification, continued
Check that the blower fan reacts correctly by setting the blower fan switch to positions 0 to 4 (including AUTO).
Select Continue.
Continue - Verification, continued
------------------------
Verification, continued
Read off diagnostic trouble codes (DTCs).
Select Continue.
Continue - Verification, continued
------------------------
Verification, continued
Erase the diagnostic trouble codes (DTCs).
Select Continue.
Continue - Verification, continued
------------------------
Verification, continued
Check that diagnostic trouble codes (DTCs) do not recur.
Do the diagnostic trouble codes (DTCs) recur?
Yes - VERIFICATION FAILED
No - VERIFIED
------------------------
VERIFIED - FAULT FOUND
VERIFICATION FAILED - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
Attempt New Test - Checking resistance
FAULT-TRACING FAILED - FAULT-TRACING FAILED
-------------------------------------------------