Signal Missing. Permanent Fault
Signal missing. Permanent fault
Checking the resistance in the signal cable
- DSA control module disconnected.
- Engine control module (ECM) disconnected.
- Breakout box connected to the engine control module (ECM).
FENIX 5.1
- Connect an ohmmeter between DSA control module connector terminal 5 and engine control module (ECM) breakout box terminal 41.
EMS 2000
- Connect an ohmmeter between DSA control module connector terminal 5 and engine control module (ECM) breakout box terminal 36.
Other information
- To connect the breakout box for DSA, see Connecting the breakout box. DSA Connecting The Breakout Box. DSA.
- To connect the breakout box for FENIX 5.1, see Connecting the breakout box. FENIX 5.1 Connecting The Breakout Box. FENIX 5.1.
- To connect the breakout box for EMS 2000, see Connecting the breakout box. EMS 2000 Connecting The Breakout Box. EMS 2000.
The ohmmeter should read approximately 0 ohms.
OK - Checking the signal cable resistance to ground
Not OK - Checking for an open-circuit
-------------------------------------------------
Checking for an open-circuit
FENIX 5.1
- Check the cable between DSA control module terminal 5 and engine control module (ECM) terminal 41 for an open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
EMS 2000
- Check the cable between DSA control module terminal 5 and engine control module (ECM) terminal 36 for an open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
Other information
- To connect the breakout box for DSA, see Connecting the breakout box. DSA Connecting The Breakout Box. DSA.
- To connect the breakout box for FENIX 5.1, see Connecting the breakout box. FENIX 5.1 Connecting The Breakout Box. FENIX 5.1.
- To connect the breakout box for EMS 2000, see Connecting the breakout box. EMS 2000 Connecting The Breakout Box. EMS 2000.
Select Continue when the fault has been remedied.
Continue - Verification
-------------------------------------------------
Checking the signal cable resistance to ground
- Ignition off.
- DSA control module disconnected.
- Engine control module (ECM) disconnected.
- Breakout box connected to the engine control module (ECM).
FENIX 5.1
- Connect an ohmmeter between breakout box terminal 41 and ground.
- On vehicles with automatic transmission: Disconnect the automatic transmission control module (TCM).
EMS 2000
- Connect an ohmmeter between breakout box terminal 36 and ground.
Other information
- To connect the breakout box for FENIX 5.1, see Connecting the breakout box. FENIX 5.1 Connecting The Breakout Box. FENIX 5.1.
- To connect the breakout box for EMS 2000, see Connecting the breakout box. EMS 2000 Connecting The Breakout Box. EMS 2000.
The ohmmeter should read infinite resistance.
OK - Checking the signal cable for a short-circuit to supply voltage
Not OK - Checking for a short-circuit
-------------------------------------------------
Checking for a short-circuit
FENIX 5.1
- Check the cable between engine control module (ECM) terminal 41 and DSA control module terminal 5 for a short-circuit to ground according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
- On vehicles with automatic transmission: Also check the cable between engine control module (ECM) terminal 41 and automatic transmission control module (TCM) terminal 38 for a short-circuit to ground according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
EMS 2000
- Check the cable between engine control module (ECM) terminal 36 and DSA control module terminal 5 for a short-circuit to ground according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
Other information
- To connect the breakout box for DSA, see Connecting the breakout box. DSA Connecting The Breakout Box. DSA.
- To connect the breakout box for FENIX 5.1, see Connecting the breakout box. FENIX 5.1 Connecting The Breakout Box. FENIX 5.1.
- To connect the breakout box for EMS 2000, see Connecting the breakout box. EMS 2000 Connecting The Breakout Box. EMS 2000.
Select Continue when the fault has been remedied.
Continue - Verification
-------------------------------------------------
Checking the signal cable for a short-circuit to supply voltage
- Ignition off.
- Connect the DSA control module.
- Connect the engine control module (ECM).
- On vehicles with automatic transmission: Connect the automatic transmission control module (TCM).
- Breakout box connected to the engine control module (ECM).
- Start the engine.
FENIX 5.1
- Connect an electrician's screwdriver (with a bulb of at least 3 W) between breakout box terminal 41 and ground.
EMS 2000
- Connect an electrician's screwdriver (with a bulb of at least 3 W) between breakout box terminal 36 and ground.
Other information
- To connect the breakout box for DSA, see Connecting the breakout box. DSA Connecting The Breakout Box. DSA.
- To connect the breakout box for FENIX 5.1, see Connecting the breakout box. FENIX 5.1 Connecting The Breakout Box. FENIX 5.1.
- To connect the breakout box for EMS 2000, see Connecting the breakout box. EMS 2000 Connecting The Breakout Box. EMS 2000.
The electricians screwdriver should notlight. Is the electrician's screwdriver unlit?
Yes - Fault cause and checking for contact resistance and oxidation
No - Checking for a short-circuit
-------------------------------------------------
Fault cause and checking for contact resistance and oxidation
The diagnostic trouble code (DTC) was caused by poor contact in the DSA control module and / or engine control module (ECM) connectors.
Check the connectors for contact resistance and oxidation and remedy according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
Select Continue when the fault has been remedied.
Continue - Verification
-------------------------------------------------
Checking for a short-circuit
FENIX 5.1
- Check the cable between engine control module (ECM) terminal 41 and DSA control module terminal 5 for a short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
- On vehicles with automatic transmission: Also check the cable between engine control module (ECM) terminal 41 and automatic transmission control module (TCM) terminal 38 for a short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
EMS 2000
- Check the cable between engine control module (ECM) terminal 36 and DSA control module terminal 5 for a short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
Other information
- To connect the breakout box for DSA, see Connecting the breakout box. DSA Connecting The Breakout Box. DSA.
- To connect the breakout box for FENIX 5.1, see Connecting the breakout box. FENIX 5.1 Connecting The Breakout Box. FENIX 5.1.
- To connect the breakout box for EMS 2000, see Connecting the breakout box. EMS 2000 Connecting The Breakout Box. EMS 2000.
Select Continue when the fault has been remedied.
Continue - Verification
-------------------------------------------------
Verification
Verification
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off.
- Reconnect the connectors, reinstall components etc.
- DSA control module connected.
- Start the engine.
- Depress the accelerator pedal quickly a few times. Release the pedal so that the engine idles each time.
- Switch off the engine.
- Ignition on.
- Read off the position of the throttle position (TP) sensor.
Fully depress the accelerator pedal several times. Check that the throttle position (TP) sensor position increases and decreases.
Is the position of the throttle position (TP) sensor OK?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFIED - FAULT FOUND
VERIFICATION FAILED - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
FAULT-TRACING FAILED - FAULT-TRACING FAILED
Attempt New Test - Checking the resistance in the signal cable
-------------------------------------------------