Checking the Function of the Governor
Checking The Function Of The Governor
- Ignition off.
- Disconnect the control module.
- Ignition on.
Connect the single wire cable between terminals 1 an 11 on the control module connector.
Connect the other cable with the double flat pins to control module connector terminal 10. Connect one cable to control module connector terminal 12.
The governor should click.
Did the governor click?
Yes - Checking the Function of the Vacuum Pump
No - Checking the Cable For the Governor