GLA-415
Diagnostic Trouble Code (DTC) Information
Condition
Diagnostic trouble code (DTC) GLA-415 is stored after approximately 2 seconds if the control module registers an error in communication with the ultrasonic sensor control module when the alarm system is powered up or when the alarm is activated or deactivated.
Condition
- None.
Possible source
- Short-circuit to ground or voltage in communication cable.
- Open-circuit in communication cable.
- The communication cable is too close to a source of interference.
Condition
- The indicator LED flashes for 15 seconds on ignition.
- The system will not trigger the alarm if there is movement in the passenger compartment.