Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Checking Power and Ground Terminal. Throttle Unit






Checking throttle unit power and ground terminal

Checking throttle unit power and ground terminal

Checking power supply
- Check fuse 11 B/2. If the fuse is blown check circuit after the fuse for a short-circuit to ground according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault
- Check power supply to throttle unit #6. Voltage should be approximately battery voltage.

Checking ground terminal
- Check ground lead between throttle unit #5 and engine ground terminal ETM 31/91 for an open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault
- Check throttle unit ground terminal for contact resistance and oxidation according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault
Remedy as necessary

Other information
- Power supply to the electronic throttle module #6 is from fuse 11 B/2 via the system relay.
- Ground terminal electronic throttle module (ETM) 31/91 for the throttle unit is located on the front of the cylinder block above the starter motor
- For information about signals, see Signal specification Signal Specifications.
- For information about circuit see the relevant wiring diagram









Was a fault detected?

Yes - FAULT FOUND

No - Fault-tracing information

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.

Do you want to exit fault-tracing?

Yes - Exit fault-tracing

No - Attempt New Test


-------------------------------------------------