Signal Missing. Intermittent Fault
Safety
- See Safety instructions for handling fuel.
- Proceed to: Checking Cables And Terminals section below.
Checking Cables And Terminals
- Check EVAP canister shut-off valve and/or engine control module (ECM) connectors for contact resistance and oxidation and loose connections.
- Check cable between EVAP canister shut-off valve terminal 1 and main relay (2/32) terminal 3 for an intermittent open-circuit.
- Check cable between EVAP canister shut-off valve terminal 2 and engine control module # B19 for an intermittent open-circuit.
- Operation done.