Signal Too High. Permanent Fault





Checking The Signal Cable
- Ignition OFF.
- Disconnect fuel pump (FP) relay (2/23) from relay base.
- Ignition ON.
- Connect a voltmeter between relay base terminal 4 and ground.
- The voltmeter should read 5-6 Volts.

If reading is OK:
^ Try a new fuel pump relay.
^ Proceed to: Verification section below.

If reading is incorrect:
^ Check cable between fuel pump relay terminal 4 and engine control module (ECM) # B19 for a short-circuit to supply voltage.
^ Proceed to: Verification section below.





Verification
After carrying out the repair, check that the fault has been remedied as follows:

- Ignition OFF.
- Fuel pump relay and engine control module connected.
- Ignition ON.
- Activate fuel pump.
- A clicking sound should be heard from the fuel pump relay when it is activated.

If reading is OK:
^ Fault corrected.

If reading is incorrect:
^ Proceed to: Fault-tracing Information section below.

Fault-tracing Information
The verification result shows that the fault persists.

- Do you want to exit fault-tracing?

Yes:
^ Fault not corrected.

No:
^ Proceed to: Checking The Signal Cable section above.