Checking Combination Relay Diode [GA5]
Checking Combination Relay Diode
- Ignition off.
- Disconnect combination relay 4-and 15-pin connector.
Connect the positive lead to a diode tester to combination relay 15-pin terminal 6 and the negative lead to terminal 10.
Diode tester should read contact.
- Switch positive and negative leads around.
Diode tester should read open circuit.
If readings are OK:
- Check ABS warning indicator working GA6. Checking ABS Warning Indicator Is Working [GA6]
If reading is incorrect:
- Try another combination relay.