Cancel Fault Code As Follows:
Display fault code again (ground test terminal for 2 - 5 seconds).
Then ground test terminal 3 times within a 1.5- 5 second period for at least 0.25 seconds each time.
Note: Spade connectors should be connected to both ends of lead used for grounding. Each grounding should be distinct and not too short.
Note: Do not switch off ignition between displaying fault code and cancelling code.
Lamp will go off for 4 seconds, then go on again for 3 seconds to confirm cancellation, and then go out.
If SRS lamp stays on, a fault has not been remedied. Display fault code again and remedy fault. Refer to separate SRS Service Manual as necessary. Cancel fault code again.
Reinstall:
- underdash panel
- air duct
- carpet
- driver's seat.
Tighten floor bolts to: 48 N-m (35 ft.lb)