Micro-Switch
1. Connect a suitable test lamp between last terminal on switch and a 12 volt power supply.2. Place a suitable feeler gauge between lower adjustment lower adjusting screw on switch lever and stop bracket.
3. With a .008 inch feeler gauge, test lamp should light.
4. With a .024 inch feeler gauge, test lamp should be OFF.
5. If necessary, place a .012 inch feeler gauge between lower adjustment screw and stop. Turn upper adjustment screw until test lamp lights and tighten adjustment screw.