Charge Air Cooler Components, Removing and Installing
Charge Air Cooler Components, Removing And Installing
NOTE:
- All hose connections for charge air system are secured by spring-type clamps or by connector couplings. For connector couplings, always note the following points:
- Use lubricant (water with no additives) as necessary. Do not use oil-based lubricants.
- Disengage connection by pulling locking clip (arrow).
- Disconnect hose/pipe without tools.
- When installing, make sure retaining tab -A- locks securely.
- VAS 5024A spring clip installation tool is recommended for installing spring-type clips.