01V, 5 SPD. A/T (FWD)
Fig. 6 Valve body,
Location: The valve body is bolted to the underside of transmission housing inside the pan.
Solenoid valves -N88-, -N89-, -N90-, -N91 -, -N92-, -N93-, -N94- are secured to the valve body of hydraulic control Type E17.
Solenoid valves -N91-, -N92-, -N93-, -N94- are known as pressure regulator valves 1 (-N215-), 2 (-N216-), 3 (-N217-) and 4 (-N218-) on the valve body of hydraulic control Type E18/2.
There are two different types of hydraulic control:
^ Transmissions with hydraulic control Type E17, on which the sender for the transmission input seed (inductive sender) is attached to the underside of the valve body.
^ Transmissions with hydraulic control Type E18/2 on which the sender for the transmission input speed (Hall sender) is attached to the transmission housing behind the valve body.