Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

01V, 5 SPD. A/T (FWD)







Fig. 6 Valve body,
Location: The valve body is bolted to the underside of transmission housing inside the pan.

Solenoid valves -N88-, -N89-, -N90-, -N91 -, -N92-, -N93-, -N94- are secured to the valve body of hydraulic control Type E17.

Solenoid valves -N91-, -N92-, -N93-, -N94- are known as pressure regulator valves 1 (-N215-), 2 (-N216-), 3 (-N217-) and 4 (-N218-) on the valve body of hydraulic control Type E18/2.

There are two different types of hydraulic control:
^ Transmissions with hydraulic control Type E17, on which the sender for the transmission input seed (inductive sender) is attached to the underside of the valve body.

^ Transmissions with hydraulic control Type E18/2 on which the sender for the transmission input speed (Hall sender) is attached to the transmission housing behind the valve body.