Sender For Fuel Gauge, Removing and Installing
Sender For Fuel Gauge, Removing And Installing
NOTE:
- When removing union nut from flange, fuel tank must not be filled more than 3/4.
- Empty fuel tank if necessary.
- Read safety precautions before beginning work.
Removing
- Removing flange.
- Disconnect connector for fuel gauge sender on underside of flange.
- If necessary, siphon fuel to lower edge of locking mechanism at sender.
- Unclip Fuel Level Sensor G at baffle housing in fuel tank and remove.
- Press locking mechanism at sender in direction of - arrow - and pull upward (figure shows sender removed).
Installing
- Insert Fuel Level Sensor G in guide on baffle housing and press down until it engages.
- Reconnect Fuel Level Sensor G connector to flange.
- Install flange and proceed with further assembly.