P2759
U340E AUTOMATIC TRANSMISSION / TRANSAXLE: AUTOMATIC TRANSAXLE SYSTEM (for Hatchback): P2759: Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)
P2759 - Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)
DESCRIPTION
Refer to P2757 P2757.
MONITOR DESCRIPTION
When an open or short in the linear solenoid valve (SLU) circuit is detected, the ECM interprets this as a fault. The ECM turns on the MIL and stores the DTC.
MONITOR STRATEGY
TYPICAL ENABLING CONDITIONS
Condition A
Condition B
Condition C
TYPICAL MALFUNCTION THRESHOLDS
Condition A and B
Condition C
COMPONENT OPERATING RANGE
WIRING DIAGRAM
INSPECTION PROCEDURE
NOTICE:
Perform the universal trip to clear permanent DTCs Reading and Clearing Diagnostic Trouble Codes.
PROCEDURE
1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)
(a) Disconnect the transmission wire connector from the transaxle.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Text in Illustration
NG -- INSPECT SHIFT SOLENOID VALVE SLU
OK -- Continue to next step.
2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
(a) Connect the transmission wire connector to the transaxle.
(b) Disconnect the ECM connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Text in Illustration
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE ECM Removal (from 07/2011)
3. INSPECT SHIFT SOLENOID VALVE SLU P2757
NG -- REPLACE SHIFT SOLENOID VALVE SLU Disassembly (from 07/2011)
OK -- REPLACE TRANSMISSION WIRE Removal (from 07/2011)