How To Proceed With Troubleshooting
HEATING / AIR CONDITIONING: SOLAR VENTILATION SYSTEM: HOW TO PROCEED WITH TROUBLESHOOTING
HINT
* Use the following procedure to troubleshoot the solar ventilation system.
* *: Use the Techstream.
1. VEHICLE BROUGHT TO WORKSHOP
NEXT -- Continue to next step.
2. INSPECT BATTERY VOLTAGE
(a) Inspect the battery voltage with the power switch off.
Standard Voltage:
11 to 14 V
If the voltage is below 11 V, recharge or replace the battery before proceeding to the next step.
NEXT -- Continue to next step.
3. CHECK FOR DTC*
(a) Check for DTCs and note any code that is output.
(b) Clear the DTCs.
(c) Recheck for DTCs.
Result:
B -- GO TO RELEVANT SYSTEM
A -- Continue to next step.
4. PROBLEM SYMPTOMS TABLE
(a) Refer to Problem Symptoms Table Solar Ventilation System.
Result:
B -- Go to step 5
A -- Continue to next step.
5. OVERALL ANALYSIS AND TROUBLESHOOTING*
(a) Terminals of ECU Solar Ventilation System
(b) Data List / Active Test Solar Ventilation System
(c) Operation Check Operation Check
(d) Inspection
NEXT -- Continue to next step.
6. ADJUST, REPAIR OR REPLACE
NEXT -- END