Sunroof / Moonroof: Service Precautions
SLIDING ROOF / CONVERTIBLE: SLIDING ROOF SYSTEM: PRECAUTION
1. PRECAUTION FOR SOLAR PANEL
(a) Before disconnecting the solar module connector, make sure to cover the entire solar module with a material such as thick fabric which blocks sunlight.
CAUTION:
The solar module generates electricity from sunlight and other light sources. If the solar module connector is touched while the solar module is generating electricity, an accidental short circuit or electric shock may occur, causing serious injury.
HINT
The solar module always generates electricity when exposed to light. When exposed to a light source such as sunlight, approximately 3.6 A and 22 V will be generated.