Air Conditioning System (for Manual Air Conditioning System)
HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for Manual Air Conditioning System): B1451: Compressor Solenoid Circuit
B1451 - Compressor Solenoid Circuit
DESCRIPTION
Through this circuit, the compressor assembly with pulley receives a refrigerant compression demand signal from the A/C amplifier.
Based on this signal, the compressor assembly with pulley changes the amount of compressor output.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. CHECK HARNESS AND CONNECTOR (COMPRESSOR ASSEMBLY WITH PULLEY - BODY GROUND)
(a) Disconnect the connector from the compressor assembly with pulley (compressor solenoid).
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
*1: for TMC Made
*2: except TMC Made
Text in Illustration
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- Continue to next step.
2. INSPECT COMPRESSOR ASSEMBLY WITH PULLEY (COMPRESSOR SOLENOID)
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
*1: for TMC Made
*2: except TMC Made
Text in Illustration
Result:
B -- REPLACE COMPRESSOR ASSEMBLY WITH PULLEY (for 2AZ-FE) Removal
C -- REPLACE COMPRESSOR ASSEMBLY WITH PULLEY (for 2ZR-FE) Removal
A -- Continue to next step.
3. CHECK HARNESS AND CONNECTOR (COMPRESSOR ASSEMBLY WITH PULLEY - A/C AMPLIFIER)
(a) Disconnect the connector from the A/C amplifier.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
*1: for TMC Made
*2: except TMC Made
Result:
B -- PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Air Conditioning System (for Manual Air Conditioning System)
C -- REPLACE AIR CONDITIONING AMPLIFIER Removal
A -- REPAIR OR REPLACE HARNESS OR CONNECTOR