Initial Inspection and Diagnostic Overview
MIRROR (EXT): POWER MIRROR CONTROL SYSTEM: DIAGNOSIS SYSTEM
1. CHECK DLC3
(a) Check the DLC3 General Information.
2. INSPECT AUXILIARY BATTERY VOLTAGE
(a) Measure the auxiliary battery voltage. With the power switch off.
Standard Voltage:
11 to 14 V
If the voltage is below 11 V, recharge or replace the auxiliary battery.