Variable Induction Control Valve: Testing and Inspection
1AR-FE INTAKE / EXHAUST: VACUUM SWITCHING VALVE (for ACIS): INSPECTION
1. INSPECT VACUUM SWITCHING VALVE ASSEMBLY (for ACIS)
(a) Measure the resistance according to the value(s) in the table below.
Text in Illustration:
Standard Resistance:
(b) If the result is not as specified, replace the air cleaner assembly.
(c) Check the vacuum switching valve operation.
(1) When vacuum is applied to port E, check that air is sucked into the filter.
Text in Illustration:
(2) If the result is not as specified, replace the air cleaner assembly.
(3) Apply battery voltage across the terminals. When vacuum is applied to port F, check that air is sucked into port E.
Text in Illustration:
(4) If the result is not as specified, replace the air cleaner assembly.