Heated Oxygen Sensor
2AZ-FXE EMISSION CONTROL: HEATED OXYGEN SENSOR: INSPECTION
1. INSPECT HEATED OXYGEN SENSOR
(a) Measure the resistance between terminals 1 (HT) and 2 (+B).
Standard resistance:
(b) If the resistance is not as specified, replace the sensor.