P0A85
HYBRID BATTERY CONTROL: HYBRID BATTERY SYSTEM: P0A85-123: Hybrid Battery Pack Cooling Fan 1
P0A85-123 - Hybrid Battery Pack Cooling Fan 1
DESCRIPTION
Refer to the circuit description for DTC P0A84-123 P0A84.
WIRING DIAGRAM
Refer to the wiring diagram for DTC P0A84-123 P0A84.
INSPECTION PROCEDURE
CAUTION:
- Before inspecting the high-voltage system, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
- After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals.
HINT
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
PROCEDURE
1. CHECK FOR DTCS (DTC P0A1F-123 IS OUTPUT)
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
(d) Check if DTCs are output.
Result:
DTC P0A1F-123 is output.
YES -- GO TO INSPECTION PROCEDURE RELEVANT TO OUTPUT DTC
NO -- Continue to next step.
2. CHECK HARNESS AND CONNECTOR (VOLTAGE)
CAUTION:
Be sure to wear insulated gloves.
(a) Remove the service plug grip Removal.
(b) Remove the battery smart unit Removal.
HINT
Do not disconnect the battery smart unit connectors.
(c) Connect the Techstream to the DLC3.
(d) Turn the power switch on (IG).
(e) Select the following menu items: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.
HINT
Check "Cooling Fan Mode 1" in the data list using the Techstream. If the "Cooling Fan Mode 1" to 6, it is not necessary to perform the Active Test.
(f) Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" active test to operate the battery cooling blower assembly.
(g) Measure the voltage according to the value(s) in the table below while the cooling fan is operating.
Standard voltage:
OK -- CHECK HV BATTERY (BATTERY TEMPERATURE SENSOR AND INLET AIR TEMPERATURE SENSOR)
NG -- Continue to next step.
3. CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - BATTERY SMART UNIT)
CAUTION:
Be sure to wear insulated gloves.
(a) Disconnect connector n2 from the battery smart unit.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance (Check for short):
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- Continue to next step.
4. CHECK BATTERY SMART UNIT (VOLTAGE)
CAUTION:
Be sure to wear insulated gloves.
(a) Turn the power switch on (IG).
(b) Measure the voltage according to the value(s) in the table below.
Standard voltage:
NG -- REPLACE BATTERY SMART UNIT Components
OK -- REPLACE BATTERY COOLING BLOWER ASSEMBLY
1. CHECK HV BATTERY (BATTERY TEMPERATURE SENSOR AND INLET AIR TEMPERATURE SENSOR)
CAUTION:
Be sure to wear insulated gloves.
(a) Disconnect connector o1 from the battery smart unit.
(b) Disconnect connector n2 from the battery smart unit.
(c) Measure the resistance according to the value(s) in the table below.
Standard resistance (Check for short):
NG -- REPLACE HV BATTERY Components
OK -- REPLACE BATTERY SMART UNIT Components